EG4 Chargeverter Plus vs GC

Both Chargeverters turn AC from a generator or the grid into 48 V DC to charge a battery bank, up to about 5 kW. The two models are not…

Two pieces of home solar equipment side by side in a utility space.

Datasheet scoreboard: 1 lines where both datasheets list a number. It counts who has the bigger (or, for idle draw, smaller) figure; it is not a quality rating and says nothing about reliability.

The short version

Plus for covered outdoor spots and low idle draw; GC for charging from a generator.

  • Chargeverter Plus: The charger will sit in a covered outdoor spot or a cold space.
  • Chargeverter GC: It will live next to a generator and you want its generator-oriented design (both models offer dry-contact generator auto-start).

Both Chargeverters turn AC from a generator or the grid into 48 V DC to charge a battery bank, up to about 5 kW. The two models are not interchangeable: the Plus is built for covered outdoor installation, the GC is built around generator use.

EG4 Chargeverter Plus vs GC: an installer’s workbench
Illustration: tools laid out before a battery install.

EG4 Chargeverter Plus vs GC: specs head to head

SpecEG4 Chargeverter PlusEG4 Chargeverter GC
Model numberCU-48-5000-OD-01CU-48|5000-GD
Charge current (adjustable)0–100 A @ 240 VAC | 0–50 A @ 120 VAC | 0–80 A @ 208 VAC0–100 A @ 240 VAC, 0–45 A @ 120 VAC, 0–50 A @ 208 VAC
Charge voltage (adjustable)40 – 60 VDC (default 40 VDC)not on datasheet
Maximum output5120 W @ 240 VAC | 2560 W @ 120 VAC5120 W @ 240 VAC, 3050 W @ 120 VAC
Idle consumption~4 W~10 W
Battery compatibility15s or 16s cell lithium batteriesnot on datasheet
Ingress protectionIP54IP21
Operating temperature-40 – 131 °F (-40 – 55 °C)14 – 131 °F (-10 – 55 °C)
Warranty (as listed)3 years (only when used indoors)3 years (only when used indoors)
Net weight13.67 lbs (6.2 kg)13 lbs (5.9 kg)
Dimensions (H×W×D)4.3×16.1×7.1 in (110×410×180 mm)not on datasheet
Battery voltagenot on datasheet48 VDC nominal
Max efficiencynot on datasheet94% @ 240 VAC, 92% @ 120 VAC

Highlighted = the better figure where both datasheets give a number (higher is better, except idle draw). More is not always better: a larger solar input, for example, needs a bigger battery and wiring to use it. Sources: EG4 Chargeverter Plus datasheet · EG4 Chargeverter GC datasheet. Checked September 30, 2026. “Not on datasheet” means the sheet does not list that line, not that the product lacks it.

What the Chargeverter Plus and Chargeverter GC numbers mean

  • Output: 5,120 W at 240 VAC for both. At 120 VAC the Plus lists 2,560 W; the GC lists 3,050 W.
  • Charge current: 0–100 A at 240 VAC on both; at 120 VAC 0–50 A (Plus) against 0–45 A (GC); at 208 VAC 0–80 A (Plus) against 0–50 A (GC).
  • Idle draw: about 4 W on the Plus, about 10 W on the GC.
  • Enclosure: IP54 on the Plus, which the maker says allows covered outdoor installation; IP21 on the GC.
  • Temperature: the Plus lists -40 to 131 °F; the GC lists 14 to 131 °F.
  • Warranty: both list 3 years, and both say it applies only when used indoors.
  • Battery: the Plus is specified for 15s or 16s lithium batteries; the GC lists a 48 VDC nominal battery.
Wiring and mounting details
Cable entry detail from a generic enclosure.

Chargeverter Plus or Chargeverter GC: who should pick which

Pick the Chargeverter Plus if…

  • The charger will sit in a covered outdoor spot or a cold space.
  • You want the lowest idle draw.
  • You charge from 208 VAC, where the Plus lists 0–80 A against 0–50 A.

Pick the Chargeverter GC if…

  • It will live next to a generator and you want its generator-oriented design (both models offer dry-contact generator auto-start).
  • You have more 120 VAC generator power to use, with 3,050 W listed.
  • It will be indoors in a space above 14 °F.

EG4 Chargeverter Plus vs GC: questions people ask

Can the Plus really go outside if the warranty says indoors only?

The maker describes the IP54 enclosure as allowing covered outdoor installation, yet both datasheets say the 3-year warranty applies only when used indoors. Read both statements and ask the seller how they apply to your install.

Which is better on a small generator?

At 120 VAC the GC lists 3,050 W of output against 2,560 W for the Plus; at 240 VAC both list 5,120 W.

Specs change with new revisions; check the current datasheets before you buy. Checked 2026-09-30. Next: size a system or compare any two models.