- Amp-hour (Ah)
- A battery’s charge capacity. Multiply by the battery’s voltage to get energy: 100 Ah at 51.2 V is 5.12 kWh.
- Battery energy (kWh)
- How much energy a battery stores. A 5 kWh battery can in principle supply 5,000 W for one hour or 500 W for ten hours, before losses.
- Cold-weather Voc
- A solar panel’s open-circuit voltage rises as it gets colder. String sizing uses the higher, cold-weather figure so the string never exceeds the inverter’s limit.
- Continuous output
- The power an inverter can supply for as long as needed, as opposed to the higher surge figure it can supply for seconds or minutes.
- Depth of discharge (DoD)
- The share of a battery’s energy you actually use. Makers often quote cycle life at a stated DoD, such as 80%.
- Hybrid inverter
- An inverter that works with solar, a battery and the grid together, and can keep the house running when the grid goes down.
- Idle consumption
- The power an inverter uses just by being on, with nothing connected. It drains the battery around the clock, so it belongs in any runtime calculation.
- Inverter
- The device that turns the DC power from panels and batteries into the AC power household appliances use.
- LFP (LiFePO4)
- Lithium iron phosphate, the battery chemistry used in EG4’s batteries.
- MPPT
- Maximum power point tracking: the circuit that adjusts the load on a solar array so it delivers as much power as the conditions allow. Each MPPT accepts a limited voltage and current.
- Nominal voltage
- The standard label for a battery’s voltage. EG4 describes its 48 V-class batteries as 51.2 V nominal.
- Off-grid inverter
- An inverter designed to run a house without a grid connection, using solar and batteries (and often a generator).
- Parallel units
- Connecting several identical inverters or batteries together to add capacity. Each datasheet states how many it supports.
- Split-phase
- The North American arrangement that supplies both 120 V and 240 V from one service. Many EG4 inverters list 120/240 V split-phase output.
- String
- Solar panels wired in series. Their voltages add up, which is why string length is limited by the inverter’s maximum PV voltage.
- Surge (peak power)
- The short-term power an inverter can supply above its continuous rating, for example to start a motor. The datasheet states how long it can last.
- Vmp
- The voltage a panel delivers at its maximum power point. It must stay inside the inverter’s MPPT voltage window.
- Voc
- Open-circuit voltage: the highest voltage a panel produces, with nothing connected. It sets the hard limit on string length.
- Watt (W) and watt-hour (Wh)
- A watt measures power at a moment; a watt-hour measures energy over time. A 100 W bulb running for ten hours uses 1,000 Wh, or 1 kWh.